CABINET | RELAY RACKS | WALLMOUNT | CABLE MANAGEMENT COOLING SOLUTIONS | LAB FURNITURE | PDU & ACCESSORIES
1-855-475-0275
BayTech


Going Green!!!
Power Factor is Real and now it's Real-Time with the MMP Power Solution
Reach operational efficiency and conform to new Green Energy standards with the MMP outlet monitoring solutions.
BayTech’s metered outlet modules report Amps, Voltage, VA, Watts, and power factor per receptacle.
Through our secure SNMP engine thresh- olds can be set to help identify equipment that is running inefficient.
Standard Features
Single Phase and Three Phase
20,30,50,60 Amp Support On, Off, Reboot option HTTPS, SSH, SSL Access Radius, TACACS Authentication Tool less Mounting
Unique Features
Modular Design
All Receptacles Monitored Power Factor per Outlet kW Hour Meter per Outlet
Current, Voltage and VA and Watts Reliable PCB Power Distribution Fail Functional Design
Metered Outlet - MMP
Additional Unique Features

Most metered power solutions only monitor input power. BayTech monitors all circuit breakers and re- ports via SNMP when thresholds met.
Outlet Metering with Power Factor

Locking C13 Receptacle Optional
Monitor individual outlets and receive current, watts, and volt-amps. Continuously monitoring equipment for power factor.

Reliable PCB Power Distribution
Reliable integrated locking clips assure power cord retention. Unique to the industry and does away with nuisance wire clips.

ISD s (Insulation Displacement) connectors are faulty and un-reliable! All Bay- Tech power solutions use reliable PCB power distribution.
Integrated Sensor Inputs

All Circuit Breakers Monitored
Eliminate the need for extra environmental monitoring devices. All BayTech power solutions offer two ports for external temperature and humidity probes.

Provide redundancy to Single Corded Devices with the ability to switch Out-of- Phase Sources in 8 to 15ms.
Providing redundancy on the power circuit level is critical to maintaining uptime. The ATS Se- ries provides a simple and reliable solution for automatically sensing power loss and seamlessly switching to a back-up circuit.
BayTech ATS transfer switch line offers a unique approach to performing the transfer by completely severing the connection between the source and load then waiting for the zero- crossing to perform the transfer. This is the driving force behind being able to perform out- of-phase transfers with a low cost solution.
Monitoring Power on the ATS is a unique feature which provides information about
• Amperage Load
• (Watts) True RMS Power
• Volt-amps
• Voltage
• Internal Temperature
By combining the ATS and the DS-Series con- sole server alerts on power and transfers can be sent via secure SNMP V3.
Automatic Trans/er Switch- ATS


Standard Features
• Out of Phase Source Switching
• 8-15ms Switching time
• Programmable Dropout Voltage
• Programmable Switchback Voltage
• SNMP and HTTP with DS-Series
• PCB-based Reliability
• Reports Volts, Current, Watts,VA
• Break-Before-Make transfer